333 research outputs found

    Interferometric detection of prostate specific antigen based on enzyme immunoassay

    Get PDF
    AbstractInterferometric detection of Prostate-specific antigen (PSA) based on enzyme immunoassay are investigated. Refractive index changes of substrate are measured for PSA detection. Michelson scheme of optical interferometer was used so as to be applicable to a disposable fluidic chip. When interferometer is used for the measurements of refractive index changes, the detection is over 8 times more sensitive than that of absorbance changes for the same amount of target protein

    Delayed Migration of Tapered Open-Cell Design Carotid Stent: A Case Report

    Get PDF
    We present a case of delayed migration of an open-cell design carotid stent, which is a rare complication following carotid artery stenting (CAS). A 65-year-old patient with carotid artery stenosis underwent CAS with an open-cell stent, initially achieving successful deployment. However, 4 months later, the stent migrated and resulted in restenosis. The patient underwent balloon angioplasty and received an additional stent, leading to improved blood flow. The rarity of stent migration, particularly in the absence of risk factors, highlights the need for clinicians to be vigilant and consider early imaging follow-up for patients at risk of this complication after CAS

    Impact of Non-vitamin K Antagonist Oral Anticoagulant Withdrawal on Stroke Outcomes

    Get PDF
    Introduction: Discontinuation of oral anticoagulants such as non-vitamin K antagonist oral anticoagulants (NOACs) may induce a hypercoagulable state, leading to severe stroke and poor outcomes. This study aimed to compare stroke outcomes between NOACs withdrawal and other prior medication statuses in patients with non-valvular atrial fibrillation (NVAF).Methods: Consecutive patients who had pre-existing NVAF and were admitted for an acute ischemic stroke or transient ischemic attack- at five hospitals between January 2013 and December 2016 were included. Prior medication status was categorized into seven groups such as no antithrombotics, antiplatelet-only, warfarin with subtherapeutic intensity, warfarin with therapeutic intensity, NOAC, warfarin withdrawal, and NOAC withdrawal. We compared initial National Institute of Health Stroke Scale (NIHSS) scores between groupsResults: Among 719 patients with NVAF, The median NIHSS score at admission was 5 (IQR 1-13). The NOAC withdrawal group had the highest median NIHSS scores at stroke onset [16, interquartile range, IQR (1–17)], followed by the warfarin withdrawal group [11, IQR (1–14, 18)], the no antithrombotic group [5, IQR (1–13, 18, 19)], and the warfarin with subtherapeutic intensity group [5, IQR (1–10, 18, 19)]. A Multivariable analysis demonstrated that NOAC withdrawal was independently associated with higher NIHSS scores at stroke onset (B 4.645, 95% confidence interval 0.384–8.906, P = 0.033). The median interval from drug withdrawal to ischemic stroke or TIA was 7 days (IQR 4-15) in the NOAC group.Conclusions: Stroke that occurred after stopping oral anticoagulants, especially NOAC, and was more severe at presentation and associated with poorer outcomes

    An intelligent method for pregnancy diagnosis in breeding sows according to ultrasonography algorithms

    Get PDF
    Pig breeding management directly contributes to the profitability of pig farms, and pregnancy diagnosis is an important factor in breeding management. Therefore, the need to diagnose pregnancy in sows is emphasized, and various studies have been conducted in this area. We propose a computer-aided diagnosis system to assist livestock farmers to diagnose sow pregnancy through ultrasound. Methods for diagnosing pregnancy in sows through ultrasound include the Doppler method, which measures the heart rate and pulse status, and the echo method, which diagnoses by amplitude depth technique. We propose a method that uses deep learning algorithms on ultrasonography, which is part of the echo method. As deep learning-based classification algorithms, Inception-v4, Xception, and EfficientNetV2 were used and compared to find the optimal algorithm for pregnancy diagnosis in sows. Gaussian and speckle noises were added to the ultrasound images according to the characteristics of the ultrasonography, which is easily affected by noise from the surrounding environments. Both the original and noise added ultrasound images of sows were tested together to determine the suitability of the proposed method on farms. The pregnancy diagnosis performance on the original ultrasound images achieved 0.99 in accuracy in the highest case and on the ultrasound images with noises, the performance achieved 0.98 in accuracy. The diagnosis performance achieved 0.96 in accuracy even when the intensity of noise was strong, proving its robustness against noise
    • …
    corecore